DN3~DN3000
S.H.Meters
Technical performance parameters
main power | AC220V 50Hz /DC24V/3.6V | |
Power consumption | <15W(Supporting power consumption with sensors) | |
Display and buttons | Display in Chinese and English, can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data setting | |
counter | Forward total, reverse total | |
output signal | Analog output | Two-way two-way, fully isolated 0~10mA/4~20mA |
Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA | ||
Frequency output | Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA | |
Alarm Output | Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun. | |
Pulse output | Forward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA | |
Matching accuracy | ± 0.5% of market value, optional ± 0.2% or 1% of indicated value | |
Damping time constant | Continuous variable from 0 ~ 100s (90%) time grading optional | |
communication | Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection | |
Loss of power | The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years) | |
Protection level | IP65 | |
Explosion-proof mark | Exs[ia]ia||cT5 |
Lining material
material | Main performance |
Polyurethane rubber | 1. Very good wear resistance coal slurry, mud, ore slurry, etc. 2. Not resistant to acid, alkaline and other corrosive or high temperature media 3. There must be no negative pressure in the pipeline |
Neoprene | 1. Very good elasticity and wear resistance 2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid 3. There must be no negative pressure in the pipeline |
Teflon F-4 PTFE | 1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions 2. Strong abrasion resistance and poor bonding performance 3. There must be no negative pressure in the pipeline |
Perchloroethylene propylene F-46(PTFE) | 1. On the basis of all functions of PTFE, the temperature of non-corrosive liquid can be increased within 140 degrees 2. Not resistant to fuming nitric acid, butyl lithium 3. There must be no negative pressure in the pipeline |
Silicone fluoride lining | Temperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems, and is not resistant to corrosion. |
Electromagnetic flowmeter electrode material
material | Corrosion performance |
316L electrode | Application: domestic / industrial water, sewage PH value: within 6/7/8 Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine |
HB | Application: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide. PH value: within 5/6/7/8 Not applicable: Oxidizing acids such as nitric acid |
HC | Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9 Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides |
Ti | Application: chloride, hypochlorite, sea water, oxidizing acid. PH value: within the range of 6/7/8/9/10 Not applicable: hydrochloric acid, sulfuric acid and other acidic media |
Ta | Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6 Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid |
Pt | Various acids, bases, salts. Not included: Royal Water |
Electrode form:
Standard, washable (scraper), replaceable
Generally, two electrodes are more symmetrical (additional + 1 with grounding electrodes), but there are also four and six electrodes.
Measuring medium:
The measured medium must be a conductive liquid (gas < 5%, solid < 60%).
Conductivity of medium > 5 μ S/cm, (water > 20) μ S/cm, gas, pure water, oil and most organic liquids have conductivity much lower than 5 μ S/cm)
Flow rate range:
0.1 --- 15 m/s
-15-15m, can measure positive and negative flow, the range ratio is 150:1, and some can even achieve 1000:1
Accuracy class:
Class 0.5, Class 1.0. Working conditions require full pipe
Technical performance parameters
main power | AC220V 50Hz /DC24V/3.6V | |
Power consumption | <15W(Supporting power consumption with sensors) | |
Display and buttons | Display in Chinese and English, can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data setting | |
counter | Forward total, reverse total | |
output signal | Analog output | Two-way two-way, fully isolated 0~10mA/4~20mA |
Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA | ||
Frequency output | Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA | |
Alarm Output | Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun. | |
Pulse output | Forward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m³ / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA | |
Matching accuracy | ± 0.5% of market value, optional ± 0.2% or 1% of indicated value | |
Damping time constant | Continuous variable from 0 ~ 100s (90%) time grading optional | |
communication | Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection | |
Loss of power | The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years) | |
Protection level | IP65 | |
Explosion-proof mark | Exs[ia]ia||cT5 |
Lining material
material | Main performance |
Polyurethane rubber | 1. Very good wear resistance coal slurry, mud, ore slurry, etc. 2. Not resistant to acid, alkaline and other corrosive or high temperature media 3. There must be no negative pressure in the pipeline |
Neoprene | 1. Very good elasticity and wear resistance 2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid 3. There must be no negative pressure in the pipeline |
Teflon F-4 PTFE | 1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions 2. Strong abrasion resistance and poor bonding performance 3. There must be no negative pressure in the pipeline |
Perchloroethylene propylene F-46(PTFE) | 1. On the basis of all functions of PTFE, the temperature of non-corrosive liquid can be increased within 140 degrees 2. Not resistant to fuming nitric acid, butyl lithium 3. There must be no negative pressure in the pipeline |
Silicone fluoride lining | Temperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems, and is not resistant to corrosion. |
Electromagnetic flowmeter electrode material
material | Corrosion performance |
316L electrode | Application: domestic / industrial water, sewage PH value: within 6/7/8 Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine |
HB | Application: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide. PH value: within 5/6/7/8 Not applicable: Oxidizing acids such as nitric acid |
HC | Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9 Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides |
Ti | Application: chloride, hypochlorite, sea water, oxidizing acid. PH value: within the range of 6/7/8/9/10 Not applicable: hydrochloric acid, sulfuric acid and other acidic media |
Ta | Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6 Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid |
Pt | Various acids, bases, salts. Not included: Royal Water |
Electrode form:
Standard, washable (scraper), replaceable
Generally, two electrodes are more symmetrical (additional + 1 with grounding electrodes), but there are also four and six electrodes.
Measuring medium:
The measured medium must be a conductive liquid (gas < 5%, solid < 60%).
Conductivity of medium > 5 μ S/cm, (water > 20) μ S/cm, gas, pure water, oil and most organic liquids have conductivity much lower than 5 μ S/cm)
Flow rate range:
0.1 --- 15 m/s
-15-15m, can measure positive and negative flow, the range ratio is 150:1, and some can even achieve 1000:1
Accuracy class:
Class 0.5, Class 1.0. Working conditions require full pipe