Application
Irrigation water meters are widely used in irrigation systems of all sizes, covering agriculture, horticulture, landscaping, golf courses and public green spaces. Its primary role is to monitor and record water usage throughout the irrigation system, providing users with information about irrigation efficiency and water costs in order to adjust and manage their water use behavior. In addition, it can help detect pipe leaks and damage, as well as prevent problems such as over-irrigation and soil nutrient loss.
Features
Used to measure the amount of water flowing through a water line in an irrigation system.
are often installed on the main line in order to monitor water use throughout the irrigation system.
Can be adjusted and changed as needed to ensure that the proper amount of water is used in the system.
typically have high accuracy and long-term stability to ensure accurate recording and calculation of water use
may have designs that prevent clogging and damage to ensure effective long-term operation.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Irrigation water meters are widely used in irrigation systems of all sizes, covering agriculture, horticulture, landscaping, golf courses and public green spaces. Its primary role is to monitor and record water usage throughout the irrigation system, providing users with information about irrigation efficiency and water costs in order to adjust and manage their water use behavior. In addition, it can help detect pipe leaks and damage, as well as prevent problems such as over-irrigation and soil nutrient loss.
Features
Used to measure the amount of water flowing through a water line in an irrigation system.
are often installed on the main line in order to monitor water use throughout the irrigation system.
Can be adjusted and changed as needed to ensure that the proper amount of water is used in the system.
typically have high accuracy and long-term stability to ensure accurate recording and calculation of water use
may have designs that prevent clogging and damage to ensure effective long-term operation.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.