Availability: | |
---|---|
Quantity: | |
LXXG-50-300MM
S.H.Meters
Application
Measuring the volume of cold (hot) water passing through the pipeline.
water meter is used for home or apartment
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Data logging: Data logging functionality can be added to irrigation water meters, which allows for the collection of water usage data over time. This data can be used to create usage reports and identify trends in water usage patterns.
Wireless connectivity: Some irrigation water meters come with wireless connectivity, which allows data to be transmitted wirelessly to a central monitoring system. This reduces the need for manual data collection and can improve accuracy and efficiency in water management.
Flow control: Flow control features can be added to irrigation water meters to enable the user to control the flow of water based on pre-set limits or conditions. This helps to prevent over-watering and water waste.
Leak detection: Some irrigation water meters are designed with leak detection capabilities, which can alert users to the presence of leaks in the system. This helps to reduce water waste and prevent damage to the irrigation system.
Multi-users: For larger irrigation systems, multi-user functionality can allow for several users to monitor and control water usage. This can facilitate more efficient and effective water management, particularly when multiple users are involved in the irrigation process.
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250
| 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1
| Q2 /Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold (hot) water passing through the pipeline.
water meter is used for home or apartment
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Data logging: Data logging functionality can be added to irrigation water meters, which allows for the collection of water usage data over time. This data can be used to create usage reports and identify trends in water usage patterns.
Wireless connectivity: Some irrigation water meters come with wireless connectivity, which allows data to be transmitted wirelessly to a central monitoring system. This reduces the need for manual data collection and can improve accuracy and efficiency in water management.
Flow control: Flow control features can be added to irrigation water meters to enable the user to control the flow of water based on pre-set limits or conditions. This helps to prevent over-watering and water waste.
Leak detection: Some irrigation water meters are designed with leak detection capabilities, which can alert users to the presence of leaks in the system. This helps to reduce water waste and prevent damage to the irrigation system.
Multi-users: For larger irrigation systems, multi-user functionality can allow for several users to monitor and control water usage. This can facilitate more efficient and effective water management, particularly when multiple users are involved in the irrigation process.
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250
| 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1
| Q2 /Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.