Availability: | |
---|---|
Quantity: | |
LXXG-50-300MM
S.H.Meters
Application
Measuring the volume of cold (hot) water passing through the pipeline.
water meter is used for home or apartment
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250
| 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
NOTE:
Installation: Proper installation and calibration of irrigation water meters is important for accurate measurement. Improper installation can lead to inaccurate readings and affect the reliability of the data collected.
Maintenance: Irrigation water meters need to be periodically inspected and maintained to ensure accurate readings. Dirt, debris, and buildup can affect the performance of the meter and lead to inaccurate readings.
Compatibility: Not all irrigation water meters are compatible with all types of irrigation systems. It is important to select the appropriate meter for the specific irrigation system in use.
Cost: The cost of purchasing and installing irrigation water meters can be high, especially for large-scale irrigation systems. However, the long-term benefits in water conservation and cost savings can outweigh the initial investment.
Climate: In very cold climates, where temperatures can drop below freezing, it is important to take steps to prevent the meter from freezing and becoming damaged. This may require insulation or other measures to protect the meter during cold weather.
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1
| Q2 /Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold (hot) water passing through the pipeline.
water meter is used for home or apartment
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250
| 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
NOTE:
Installation: Proper installation and calibration of irrigation water meters is important for accurate measurement. Improper installation can lead to inaccurate readings and affect the reliability of the data collected.
Maintenance: Irrigation water meters need to be periodically inspected and maintained to ensure accurate readings. Dirt, debris, and buildup can affect the performance of the meter and lead to inaccurate readings.
Compatibility: Not all irrigation water meters are compatible with all types of irrigation systems. It is important to select the appropriate meter for the specific irrigation system in use.
Cost: The cost of purchasing and installing irrigation water meters can be high, especially for large-scale irrigation systems. However, the long-term benefits in water conservation and cost savings can outweigh the initial investment.
Climate: In very cold climates, where temperatures can drop below freezing, it is important to take steps to prevent the meter from freezing and becoming damaged. This may require insulation or other measures to protect the meter during cold weather.
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1
| Q2 /Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.