220v sewage digital electromagnetic flowmeter with display

Product Description

Technical performance parameters

main power

AC220V 50Hz /DC24V/3.6V

Power consumption

<15WSupporting power consumption with sensors

Display and buttons

Display in Chinese and English, can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). 4 membrane touch switches for data setting

counter

Forward total, reverse total

output signal

Analog output

Two-way two-way, fully isolated 0~10mA/4~20mA

Load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA

Frequency output

Forward and reverse flow output, the upper limit of output frequency can be set within 1 ~ 5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA

Alarm Output

Two open-collector alarm outputs with photoelectric isolation transistors. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun.

Pulse output

Forward and reverse flow output, the upper limit of output pulse can reach 5000CP / S. The pulse equivalent is 0.0001 ~ 1.0m⊃3; / P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. External power supply is not greater than 35V, the maximum current of the collector when conducting is 50mA

Matching accuracy

± 0.5% of market value, optional ± 0.2% or 1% of indicated value

Damping time constant

Continuous variable from 0 ~ 100s (90%) time grading optional

communication

Optional RS232C or RS485 serial communication interface, HART communication protocol, with anti-lightning protection

Loss of power

The internal design of the instrument has a power-off clock, which can store 16 drop-out records (10 years)

Protection level

IP65

Explosion-proof mark

Exs[ia]ia||cT5

Lining material

material

Main performance

Polyurethane rubber

1. Very good wear resistance coal slurry, mud, ore slurry, etc.

2. Not resistant to acid, alkaline and other corrosive or high temperature media

3. There must be no negative pressure in the pipeline

Neoprene

1. Very good elasticity and wear resistance

2. Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 liquid

3. There must be no negative pressure in the pipeline

Teflon F-4 PTFE

1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions

2. Strong abrasion resistance and poor bonding performance

3. There must be no negative pressure in the pipeline

Perchloroethylene propylene F-46(PTFE)

1. On the basis of all functions of PTFE, the temperature of non-corrosive liquid can be increased within 140 degrees

2. Not resistant to fuming nitric acid, butyl lithium

3. There must be no negative pressure in the pipeline

Silicone fluoride lining

Temperature resistance: 70 degrees, mainly high temperature. It can be used to measure hot water in heating systems, and is not resistant to corrosion.

Electromagnetic flowmeter electrode material

material

Corrosion performance

316L electrode

Application: domestic / industrial water, sewage

PH value: within 6/7/8

Not applicable: corrosive media such as hydrofluoric acid / hydrochloric acid / chlorine / iodine

HB

Application: certain concentration of hydrofluoric acid and other oxidizing acids and non-oxidizing hydrochloric acid, alkali solution with a concentration of not less than 70% sodium hydroxide.

PH value: within 5/6/7/8

Not applicable: Oxidizing acids such as nitric acid

HC

Application: corrosion resistance to oxidizing salts or environments containing other oxidants, especially to seawater. PH value is within: 6/7/8/9

Not applicable: hydrochloric acid, dilute sulfuric acid, phosphoric acid and other reducing acids and chlorides

Ti

Application: chloride, hypochlorite, sea water, oxidizing acid.

PH value: within the range of 6/7/8/9/10

Not applicable: hydrochloric acid, sulfuric acid and other acidic media

Ta

Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid.

PH value: within 3/4/5/6

Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid

Pt

Various acids, bases, salts. Not included: Royal Water

Calibration:

Electromagnetic flow meter with wide range of diameters from DN3 to DN3000


Pressure rating:

The actual maximum working pressure must be less than the rated working pressure of the flow meter.

Rated pressure below DN300 is 1.6Mpa

DN350~DN1000 rated pressure is 1.0Mpa

The rated pressure above DN1200 is 0.6Mpa

Flow meters of the same caliber for different products may have different rated pressures, and overpressures can be customized


Ambient temperature:

The working temperature environment is general -25 ~60 C.


Operating temperature:

Reference Lining Material Properties

Electromagnetic Flowmeter with Remote Display Intelligent Sewage

rs 485 low price liquid electromagnetic flowmeter with signal pulse output made in china

sewage low price flowmeter with remote display with rs 485 made in china

sewage intelligent industrial fluids small electromagnetic flowmeter

220v sensor wifi intelligent electromagnetic flowmeter price made in china