Color: | |
---|---|
Size: | |
Material: | |
R: | |
Availability: | |
Quantity: | |
LXLC-50-300MM
S.H.Meters
Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline.
Dry-dial, Magnetic drive sensitive action, small pressure loss.
Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service.
Selected high quality materials for steady & reliable charac teristic.
Technical data conform to international standard ISO 4064.
With high accuracy
Product accessories include connectors, filters, connection accessories, pipe accessories, Flange, filter
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note
Installation location: Industrial water meters should be installed in an easily accessible location for readings and maintenance. Also, a location with a relatively stable water flow should be chosen to ensure the accuracy of the measurement.
Pipe diameter: It is very important to choose the correct size of the industrial water meter. If the diameter of the water meter is too small, it will result in a restricted water flow, which will affect the accuracy of the measurement.
Water quality: Changes in water quality can also affect the accuracy of an industrial water meter. If there are a lot of impurities or particles in the water, it may affect the sensors inside the water meter and lead to incorrect measurement results.
Maintenance: Regular maintenance of the industrial water meter is very important to avoid corrosion and damage inside the meter, as well as to ensure the accuracy of the measurement. Regular cleaning of the water meter and replacement of damaged parts is necessary.
Temperature: The measurement accuracy of industrial water meters is affected by temperature, so they should be installed in a constant temperature environment to ensure that the water flow temperature is not too high or too low.
Pressure: Water meters need to be able to withstand high pressures and flow rates. Ensure that the operating range of the water meter is appropriate for the pressure and flow rate of the water flow in the environment in which it is used.
Calibration: Periodically calibrate industrial water meters to ensure their accuracy. The frequency of calibration depends on usage and it is recommended that calibration be performed at least once a year.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline.
Dry-dial, Magnetic drive sensitive action, small pressure loss.
Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service.
Selected high quality materials for steady & reliable charac teristic.
Technical data conform to international standard ISO 4064.
With high accuracy
Product accessories include connectors, filters, connection accessories, pipe accessories, Flange, filter
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note
Installation location: Industrial water meters should be installed in an easily accessible location for readings and maintenance. Also, a location with a relatively stable water flow should be chosen to ensure the accuracy of the measurement.
Pipe diameter: It is very important to choose the correct size of the industrial water meter. If the diameter of the water meter is too small, it will result in a restricted water flow, which will affect the accuracy of the measurement.
Water quality: Changes in water quality can also affect the accuracy of an industrial water meter. If there are a lot of impurities or particles in the water, it may affect the sensors inside the water meter and lead to incorrect measurement results.
Maintenance: Regular maintenance of the industrial water meter is very important to avoid corrosion and damage inside the meter, as well as to ensure the accuracy of the measurement. Regular cleaning of the water meter and replacement of damaged parts is necessary.
Temperature: The measurement accuracy of industrial water meters is affected by temperature, so they should be installed in a constant temperature environment to ensure that the water flow temperature is not too high or too low.
Pressure: Water meters need to be able to withstand high pressures and flow rates. Ensure that the operating range of the water meter is appropriate for the pressure and flow rate of the water flow in the environment in which it is used.
Calibration: Periodically calibrate industrial water meters to ensure their accuracy. The frequency of calibration depends on usage and it is recommended that calibration be performed at least once a year.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.