Color: | |
---|---|
Size: | |
Material: | |
R: | |
Availability: | |
Quantity: | |
LXLC-50-300MM
S.H.Meters
Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
Accurate measurement: Irrigation water meters can accurately measure water flow and water consumption time, so that users can better control water consumption behavior and reduce water consumption costs.
Automated control: Used in conjunction with other sensors and devices, irrigation water meters allow for automated control and management, improving system efficiency and reliability.
Easy to install: Irrigation water meters are usually small, lightweight and easy to install, making them suitable for a variety of scenarios.
Easy to maintain: Most irrigation water meters are simple in structure and easy to maintain and service. Regular inspection and calibration ensure their working accuracy and longevity.
Water conservation: Through precise measurement and automated control, irrigation water meters can help users better conserve water and reduce water waste.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Why choose us ?
1.Professional R & D team support the customization request including the meters parts, various signal output, the data management system and charge system. The aim is to achieve the water metering system localization .
2.We have a strict quality management system, and experienced technical engineers are in charge of production and calibration, so as to ensure the quality of each water meter before delivery. For regular order provide each water meter test result and inspection report.
3.About the delivery ability side , we have stable stock. For sample and trial order, we have the special production line to make sure the fast delivery. and large orders also can guarantee the delivery time.
4.Our fund is guaranteed, the payment method is flexible.
5. As to the after-sales service system, we are building the complete after-sell services station in overseas markets and looking for more local partners can start the cooperation with us.
Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
Accurate measurement: Irrigation water meters can accurately measure water flow and water consumption time, so that users can better control water consumption behavior and reduce water consumption costs.
Automated control: Used in conjunction with other sensors and devices, irrigation water meters allow for automated control and management, improving system efficiency and reliability.
Easy to install: Irrigation water meters are usually small, lightweight and easy to install, making them suitable for a variety of scenarios.
Easy to maintain: Most irrigation water meters are simple in structure and easy to maintain and service. Regular inspection and calibration ensure their working accuracy and longevity.
Water conservation: Through precise measurement and automated control, irrigation water meters can help users better conserve water and reduce water waste.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Why choose us ?
1.Professional R & D team support the customization request including the meters parts, various signal output, the data management system and charge system. The aim is to achieve the water metering system localization .
2.We have a strict quality management system, and experienced technical engineers are in charge of production and calibration, so as to ensure the quality of each water meter before delivery. For regular order provide each water meter test result and inspection report.
3.About the delivery ability side , we have stable stock. For sample and trial order, we have the special production line to make sure the fast delivery. and large orders also can guarantee the delivery time.
4.Our fund is guaranteed, the payment method is flexible.
5. As to the after-sales service system, we are building the complete after-sell services station in overseas markets and looking for more local partners can start the cooperation with us.