DN15-DN40
S.H.Meters
AMI SYSTEM INTRODUCTION SIMPLE IS SMART
System structure diagram as follows
· server send commands to the data concentrator through network;
· concentrator transforms the received commands into radio signal and send the signal to the water meters;
· water meters respond and execute the commands accordingly;
· Water meters deliver the result or data back to the management center as per the original route after the actions finished.
Service
· Quality Gurantee: Water meter for 1 year;
· Support install guide & test in site;
· Date sheet can be sent to other management system easily.
Brief introduction
Ultrasonic water meter is a new type of water meter that detects the time difference caused by the change of velocity when the ultrasonic beam propagates in the opposite direction of the water, and analyzes and processes the flow rate of water to further calculate the flow of water.
Overview
·Features long service time and high accuracy
·Threaded connection digital water meter, used in industrial pipelines, suitable for high pressure environment, can choose whether to install pulse output
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Automatic leak measurement
Benefits
Compatible with Various Pipework: Ultrasonic water meters are compatible with various pipework materials, making them a versatile solution for water management.
Cost-Effective: Ultrasonic water meters have a long lifespan, making them a cost-effective solution for water management.
Record Keeping: Ultrasonic water meters can keep long-term records of water consumption, making it easy to track and manage water usage over extended periods.
High Flow Range: Ultrasonic water meters can measure a wide flow range, providing accurate readings from low to high water flow rates.
Bi-Directional Flow Measurement: Ultrasonic water meters can measure both forward and reverse flow, providing accurate readings for both incoming and outgoing water flow.
Outline dimensional drawing
Dimension
Nominal Diameter | Length L | Length L1 | Width B | Height H1 | Connecting Thread | |
mm | d | D | ||||
15 | 258 | 165 | 95 | 95 | R1/2B | G3/4B |
20 | 299 | 195 | 95 | 100 | R3/4 | G1B |
25 | 345 | 225 | 95 | 108 | R1 | G1 1/4B |
32 | 305 | 180 | 95 | 120 | R1 1/4 | G1 1/2B |
40 | 330 | 200 | 95 | 125 | R1 1/2 | G2B |
Technical specifications
Item | Unit | Details | ||||
Nominal diameter | mm | 15 | 20 | 25 | 32 | 40 |
Q3/Q1 | R200 | |||||
Overlolad flow(Q4) | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 |
Nominal flow(Q3) | m³/h | 2.5 | 4 | 6.3 | 10 | 16 |
Transitional flow(Q2) | m³/h | 0.02 | 0.032 | 0.05 | 0.08 | 0.128 |
Minimum flow(Q1) | m³/h | 0.013 | 0.02 | 0.032 | 0.05 | 0.08 |
Accuracy class | class 2 | |||||
Battery life | 8 years | |||||
Temperature class | T30/T50 | |||||
Pressure class | ≤0.063Mpa | |||||
Pressure loss class | p63 | |||||
Flow prefile sensitivity class | U10/D5 | |||||
environmental class | Class B,M1 | |||||
electromagnetic environment class | E1 | |||||
Working pressure | 1.6Mpa | |||||
Max flow indication | 999999.9m³ | |||||
Installation position | Horizontal or Vertical |
AMI SYSTEM INTRODUCTION SIMPLE IS SMART
System structure diagram as follows
· server send commands to the data concentrator through network;
· concentrator transforms the received commands into radio signal and send the signal to the water meters;
· water meters respond and execute the commands accordingly;
· Water meters deliver the result or data back to the management center as per the original route after the actions finished.
Service
· Quality Gurantee: Water meter for 1 year;
· Support install guide & test in site;
· Date sheet can be sent to other management system easily.
Brief introduction
Ultrasonic water meter is a new type of water meter that detects the time difference caused by the change of velocity when the ultrasonic beam propagates in the opposite direction of the water, and analyzes and processes the flow rate of water to further calculate the flow of water.
Overview
·Features long service time and high accuracy
·Threaded connection digital water meter, used in industrial pipelines, suitable for high pressure environment, can choose whether to install pulse output
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Automatic leak measurement
Benefits
Compatible with Various Pipework: Ultrasonic water meters are compatible with various pipework materials, making them a versatile solution for water management.
Cost-Effective: Ultrasonic water meters have a long lifespan, making them a cost-effective solution for water management.
Record Keeping: Ultrasonic water meters can keep long-term records of water consumption, making it easy to track and manage water usage over extended periods.
High Flow Range: Ultrasonic water meters can measure a wide flow range, providing accurate readings from low to high water flow rates.
Bi-Directional Flow Measurement: Ultrasonic water meters can measure both forward and reverse flow, providing accurate readings for both incoming and outgoing water flow.
Outline dimensional drawing
Dimension
Nominal Diameter | Length L | Length L1 | Width B | Height H1 | Connecting Thread | |
mm | d | D | ||||
15 | 258 | 165 | 95 | 95 | R1/2B | G3/4B |
20 | 299 | 195 | 95 | 100 | R3/4 | G1B |
25 | 345 | 225 | 95 | 108 | R1 | G1 1/4B |
32 | 305 | 180 | 95 | 120 | R1 1/4 | G1 1/2B |
40 | 330 | 200 | 95 | 125 | R1 1/2 | G2B |
Technical specifications
Item | Unit | Details | ||||
Nominal diameter | mm | 15 | 20 | 25 | 32 | 40 |
Q3/Q1 | R200 | |||||
Overlolad flow(Q4) | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 |
Nominal flow(Q3) | m³/h | 2.5 | 4 | 6.3 | 10 | 16 |
Transitional flow(Q2) | m³/h | 0.02 | 0.032 | 0.05 | 0.08 | 0.128 |
Minimum flow(Q1) | m³/h | 0.013 | 0.02 | 0.032 | 0.05 | 0.08 |
Accuracy class | class 2 | |||||
Battery life | 8 years | |||||
Temperature class | T30/T50 | |||||
Pressure class | ≤0.063Mpa | |||||
Pressure loss class | p63 | |||||
Flow prefile sensitivity class | U10/D5 | |||||
environmental class | Class B,M1 | |||||
electromagnetic environment class | E1 | |||||
Working pressure | 1.6Mpa | |||||
Max flow indication | 999999.9m³ | |||||
Installation position | Horizontal or Vertical |