Availability: | |
---|---|
Quantity: | |
LXXG-50-300MM
S.H.Meters
Woltman Water Meter agricultur DN300 elarge caliber dry dial
Application
Cost Savings - By managing water usage more effectively, farmers can reduce their water usage costs, minimize energy consumption, and avoid costly repairs and maintenance.
Easy Installation - Many irrigation water meters are easy to install with minimal technical skills, and they generally require little-to-no maintenance.
Improved Efficiency - New water meter technologies can provide real-time alerts and data on water usage patterns, eliminating the need for manual tracking. This can help farmers manage their irrigation systems more efficiently.
Remote Monitoring - Wireless communication features allow farmers to monitor irrigation water usage remotely, enabling them to track water usage patterns from a central location, reducing unnecessary site visits.
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250 | 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
NOTE
The flange dimension conforms to ISO7005-1:1988 standard. Flange standard can be customized. Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1 | Q2 /Q1 | Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Woltman Water Meter agricultur DN300 elarge caliber dry dial
Application
Cost Savings - By managing water usage more effectively, farmers can reduce their water usage costs, minimize energy consumption, and avoid costly repairs and maintenance.
Easy Installation - Many irrigation water meters are easy to install with minimal technical skills, and they generally require little-to-no maintenance.
Improved Efficiency - New water meter technologies can provide real-time alerts and data on water usage patterns, eliminating the need for manual tracking. This can help farmers manage their irrigation systems more efficiently.
Remote Monitoring - Wireless communication features allow farmers to monitor irrigation water usage remotely, enabling them to track water usage patterns from a central location, reducing unnecessary site visits.
Features
·Removable element structure, easy installation and maintenance.
·Dry-dial, Magnetic drive.
·Large flow capacity, small pressure loss.
·Resist water hummer and pollution.
·Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a long term service.
·Selected high quality materials for steady and reliable characteristic.
·Technical data conform to international standard ISO 4064/ISO9100.
·With high accuracy
·Product accessories include connectors, filters, connection accessories, pipe accessories,Flange, filter
Optional Features
·Plastic register, copper register and full glass register.
·Accuracy: R=25/20/50/class a.
·Size: DN50-DN300.
·Cold / Hot water.
·Water meter temperature: 40℃-90℃
·Reed switch option.
·Flange standard can be choose.
·360 degree rotate can be choose.
·Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
·Working pressure: PN16/25.
·Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
·Water temperature: 0.1℃~50℃ (0.1℃~90℃ for hot water meter).
·Water pressure: ≤1.0Mpa (1.6MPa on request).
Maximum Permissible Errors
·In the lower zone from qmin inclusive up to but excluding qt is ±5%.
·In the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter).
Dimensions
Type | size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-m) | |||
LXXG-50 | 50 | 200 | 253 | 165 | 125 | 4-M16 |
LXXG-65 | 65 | 200 | 268 | 185 | 145 | 4-M16 |
LXXG-80 | 80 | 225 | 284 | 200 | 160 | 8-M16 |
LXXG-100 | 100 | 250 | 295 | 220 | 180 | 8-M16 |
LXXG-125 | 125 | 250 | 310 | 250 | 210 | 8-M16 |
LXXG-150 | 150 | 300 | 339 | 285 | 240 | 8-M16 |
LXXG-200 | 200 | 350 | 382 | 340 | 295 | 8-M20(1.0MPa) |
12-M20(1.6MPa) | ||||||
LXXG-250 | 250 | 450 | 438 | 395 | 350 | 12-M20(1.0MPa) |
405 | 355 | 12-M24(1.6MPa) | ||||
LXXG-30 | 300 | 500 | 488 | 445 | 400 | 12-M20(1.0MPa |
460 | 410 | 12-M24(1.6MPa) |
NOTE
The flange dimension conforms to ISO7005-1:1988 standard. Flange standard can be customized. Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN50-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3 /Q1 | Q2 /Q1 | Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.25 | 25 | 20 | 4 | 5 | 1.25 | 0.002 | 0.0002 | 999,999 | 999,999 |
65 | 50 | 40 | 20 | 4 | 8 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
80 | 78.75 | 63 | 20 | 4 | 12.6 | 3.15 | 0.002 | 0.002 | 999,999 | 9,999,999 |
100 | 125 | 100 | 20 | 4 | 20 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
125 | 200 | 160 | 20 | 4 | 32 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
150 | 312.5 | 250 | 20 | 4 | 50 | 12.5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
200 | 500 | 400 | 20 | 4 | 80 | 20 | 0.002 | 0.002 | 999,999 | 9,999,999 |
250 | 787.5 | 630 | 20 | 4 | 126 | 31.5 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
300 | 1250 | 1000 | 20 | 4 | 200 | 50 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below, the two reed switches woud be operated “ON” OR”OFF” respectively by the magnet fitted to the pointer or gear during its running on the register, but never “ON” at the same time ,unless the out- magnet attackes.
The two reed switches operate two “ON” and two “OFF” in one round of the pointer or the gear means one signal output, this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating, so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.