Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
High accuracy: Irrigate water meters need to measure water usage with high accuracy, and are typically designed to be able to measure low flow rates.
Durability: Irrigate water meters need to be durable and able to withstand harsh outdoor environments, including extreme temperatures, UV radiation, and exposure to dirt and debris.
Tamper-resistant design: Many irrigate water meters have tamper-resistant features to prevent unauthorized adjustments or tampering.
Easy installation: Many irrigate water meters can be installed easily on existing irrigation systems without requiring significant modifications to the system.
Remote monitoring and data transmission: Some irrigate water meters can transmit data wirelessly to a remote monitoring system, allowing users to monitor water usage in real time and make adjustments as necessary.
Low maintenance requirements: Irrigate water meters should ideally require minimal maintenance over their lifespan, to ensure that they continue to provide accurate and reliable measurements.
Compatibility with different pipe sizes and materials: Irrigate water meters need to be compatible with various pipe sizes and materials commonly used in irrigation systems.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty
All meters will be guaranteed against defects in workmanship and material for a period of one(1) year from the date of acceotance.Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold(hot) water passing through the pipeline.
Water meter is used for home or apartment.
Features
High accuracy: Irrigate water meters need to measure water usage with high accuracy, and are typically designed to be able to measure low flow rates.
Durability: Irrigate water meters need to be durable and able to withstand harsh outdoor environments, including extreme temperatures, UV radiation, and exposure to dirt and debris.
Tamper-resistant design: Many irrigate water meters have tamper-resistant features to prevent unauthorized adjustments or tampering.
Easy installation: Many irrigate water meters can be installed easily on existing irrigation systems without requiring significant modifications to the system.
Remote monitoring and data transmission: Some irrigate water meters can transmit data wirelessly to a remote monitoring system, allowing users to monitor water usage in real time and make adjustments as necessary.
Low maintenance requirements: Irrigate water meters should ideally require minimal maintenance over their lifespan, to ensure that they continue to provide accurate and reliable measurements.
Compatibility with different pipe sizes and materials: Irrigate water meters need to be compatible with various pipe sizes and materials commonly used in irrigation systems.
Optional Features
Plastic register, copper register and full glass register.
Accuracy: R=class b.
Size: DN50-300mm.
Cold / Hot water.
Reed switch option.
Flange standard can be choose.
360 degree rotate can be choose.
Cast iron, Ductile iron, stainless steel,GG25,GGG50,SS304,SS316 body can be choose.
Color can be change on body and cover.
Provide pulse output/rs485 modbus/wired remote/pulse splitter/pulse read display
Working Condition
Water temperature: 0.1℃~50℃ ( 0.1℃~90℃ for hot water meter).
Water pressure: PN10/16/25.
Maximum Permissible Errors
in the lower zone from qmin inclusive up to but excluding qt is ±5%.
in the upper zone from qt inclusive up to and including qs is ±2%(±3% for hot water meter).
Dimensions
Type | Size | Length | Height | Connecting Flange | ||
mm | D1 Outside Diameter | D2 Bolt Circle Diameter | Connecting Bolts(n-M) | |||
LXLC-50 | 50 | 200 | 214 | 165 | 125 | 4-M16 |
LXLC-65 | 65 | 200 | 224 | 185 | 145 | 4-M16 |
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 |
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 |
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 |
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 |
LXLC-200
| 200 | 350 | 346 | 340 | 295 | 8-M20(1.0DE) |
12-M20(1.6MPa) | ||||||
LXLC-250
| 250 | 450 | 434 | 395(1.0MPa) | 350(1.0MPa) | 12-M20(1.0MPa) |
405(1.6MPa) | 355(1.6MPa) | 12-M24(1.6MPa) | ||||
LXLC-300
| 300 | 500 | 459 | 445(1.0MPa) | 400(1.0MPa) | 12-M20(1.0MPa) |
460(1.6MPa) | 410(1.6MPa) | 12-M24(1.6MPa) |
Note:The flange dimension conforms to ISO7005-1:1988 standard.Flange standard can be customized.Order for products of special requirements is also accepted.
Pulse Position
Size | Pulse Position |
DN15-65 | 10/100/1000L/Pulse |
DN80-200 | 100/1000L/Pulse |
DN250-300 | 1000L/Pulse |
Pressure Loss Curve
Flow Technique Specification
Nominal Flow | Maximum Flow Q4 | Permanent Flow Q3 | Q3/Q1
| Q2/Q1
| Transitional Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading | ||
Full Glass Seal | Common Seal | Full Glass Seal | Common Seal | |||||||
DN | m³/h | m³/h | m³ | |||||||
50 | 31.3 | 25 | 50 | 1.6 | 0.8 | 0.5 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 2 | |||||||||
65 | 50 | 40 | 50 | 1.6 | 1.3 | 0.8 | 0.0005 | 0.0002 | 999,999 | 999,999 |
4 | 3.2 | |||||||||
80 | 78.8 | 63 | 50 | 1.6 | 2 | 1.3 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 5 | |||||||||
100 | 125 | 100 | 50 | 1.6 | 3.2 | 2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 8 | |||||||||
125 | 200 | 160 | 50 | 1.6 | 4 | 3.2 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 12.8 | |||||||||
150 | 312.5 | 250 | 50 | 1.6 | 8 | 5 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 20 | |||||||||
200 | 500 | 400 | 50 | 1.6 | 12.8 | 8 | 0.002 | 0.002 | 999,999 | 9,999,999 |
4 | 32 | |||||||||
250 | 787.5 | 630 | 25 | 1.6 | 40.3 | 25.2 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 100.8 | |||||||||
300 | 1250 | 1000 | 25 | 1.6 | 64 | 40 | 0.02 | 0.02 | 9,999,999 | 99,999,999 |
4 | 160 |
The Operation Description Of The Two Reed Switches System
Please see the diagram of the two reed switches system below,the two reed switches woud be operated "ON" or "OFF" respectively by the magnet fitted to the pointer or gear during its running on the register,but never "ON" at the same time,unless the out-magnet attackes.
The two reed switches operate two "ON" and two "OFF" in one round of the pointer or the gear means one signal output,this principle prevent the loss or overcounting of the signal output due to the switches joggling or the pipe vibrating,so assures reliability of the signal output.
Warranty