Cold woltman pulse output farm water meter
Type
LXLC(R)-50~500(mm) / 2inch~20inch
Material
Cast iron body /Ductile iron body
This type of water meter can be used for a remote reading transmission system as equipped with a built-in sensor.
Application
--Measuring the volume of cold (hot) water passing through the pipeline in agriculture irrigation system and industrial system.
Feature
--Removable element structure, easy installation and maintenance, register for
universal use within this range detachable without Removing the meter fromthe
pipeline;
--Dry-dial,Magnetic drive sensitive action, small pressure loss;
--Vacuum sealed register ensures the dial keep free fromfog and Keep the
reading clear in a long term service;
--Selected high quality materials for steady & reliable characteristic;
--Technical data conformto international standard ISO 4064 Class B.
Working condition
Water temperature: 0.1℃~40℃ ( 0.1℃~90℃ for hot water meter)
Water pressure: ≤1Mpa (1.6MPa for special requirement)
Maximum permissible errors
(1)in the lower zone from qmin inclusive up to but excluding qt is ±5%
(2)in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)
NOTE
The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.
MAIN TECHNICAL SPECIFICATIONS
Type | Size(mm) | Class | Qs Overload Flow | Qp Permanent Flow | Qt Transitinal Flow | Qmin Min. Flow | Min. Reading | Max. Reading |
m³/h | m³ | |||||||
LXLC-40 | 40 | B | 20 | 10 | 2 | 0.300 | 0.01 | 999,999 |
LXLC-50 | 50 | B | 30 | 15 | 3 | 0.45 | 0.01 | 999,999 |
LXLC-65 | 65 | B | 50 | 25 | 5 | 0.75 | 0.01 | 999,999 |
LXLC-80 | 80 | B | 80 | 40 | 8 | 1.20 | 0.01 | 999,999 |
LXLC-100 | 100 | B | 130 | 60 | 12 | 1.80 | 0.01 | 999,999 |
LXLC-125 | 125 | B | 200 | 100 | 20 | 3.00 | 0.01 | 999,999 |
LXLC-150 | 150 | B | 300 | 150 | 30 | 4.50 | 0.01 | 999,999 |
LXLC-200 | 200 | B | 500 | 250 | 50 | 7.50 | 0.01 | 999,999 |
LXLC-250 | 250 | B | 800 | 400 | 80 | 12.00 | 0.01 | 999,999 |
LXLC-300 | 300 | B | 1200 | 600 | 120 | 18.00 | 0.01 | 999,999 |
LXLC-400 | 400 | B | 2000 | 100 | 200 | 30.00 | 0.01 | 999,999 |
LXLC-500 | 500 | B | 3000 | 1500 | 300 | 45.00 | 0.01 | 999,999 |
DIMENSIONS
Type | Size | Length | Width | Height | Connecting flange (mm ) | Weight | ||
mm | φD1 - Outside diameter | φD2-Bolt circle diameter | Connecting Bolts (n-M) | KG | ||||
LXLC-50 | 50 | 200 | 175 | 257 | 165 | 125 | 4×M16 | 12 |
LXLC-65 | 65 | 200 | 185 | 267 | 185 | 145 | 4×M16 | 13 |
LXLC-80 | 80 | 225 | 200 | 277 | 200 | 160 | 4×M16 | 15 |
LXLC-100 | 100 | 250 | 220 | 287 | 220 | 180 | 4×M16 | 19 |
LXLC-125 | 125 | 250 | 245 | 297 | 245 | 210 | 4×M16 | 22 |
LXLC-150 | 150 | 250 | 285 | 375 | 285 | 240 | 8×M20 | 47 |
LXLC-200 | 200 | 350 | 345 | 400 | 340 | 295 | 8×M20 | 48 |
LXLC-250 | 250 | 350 | 395 | 484 | 385 | 350 | 8×M20 | 110 |
LXLC-300 | 300 | 450 | 445 | 506 | 445 | 400 | 12×M20 | 115 |
LXLC-400 | 400 | 500 | 565 | 621 | 565 | 525 | 16×M24 | 180 |
LXLC-500 | 500 | 500 | 670 | 725 | 670 | 620 | 20×M24 | 330 |
cold water meter
Cold woltman pulse output farm water meter
Type
LXLC(R)-50~500(mm) / 2inch~20inch
Material
Cast iron body /Ductile iron body
This type of water meter can be used for a remote reading transmission system as equipped with a built-in sensor.
Application
--Measuring the volume of cold (hot) water passing through the pipeline in agriculture irrigation system and industrial system.
Feature
--Removable element structure, easy installation and maintenance, register for
universal use within this range detachable without Removing the meter fromthe
pipeline;
--Dry-dial,Magnetic drive sensitive action, small pressure loss;
--Vacuum sealed register ensures the dial keep free fromfog and Keep the
reading clear in a long term service;
--Selected high quality materials for steady & reliable characteristic;
--Technical data conformto international standard ISO 4064 Class B.
Working condition
Water temperature: 0.1℃~40℃ ( 0.1℃~90℃ for hot water meter)
Water pressure: ≤1Mpa (1.6MPa for special requirement)
Maximum permissible errors
(1)in the lower zone from qmin inclusive up to but excluding qt is ±5%
(2)in the upper zone from qt inclusive up to and including qs is ±2% (±3% for hot water meter)
NOTE
The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.
MAIN TECHNICAL SPECIFICATIONS
Type | Size(mm) | Class | Qs Overload Flow | Qp Permanent Flow | Qt Transitinal Flow | Qmin Min. Flow | Min. Reading | Max. Reading |
m³/h | m³ | |||||||
LXLC-40 | 40 | B | 20 | 10 | 2 | 0.300 | 0.01 | 999,999 |
LXLC-50 | 50 | B | 30 | 15 | 3 | 0.45 | 0.01 | 999,999 |
LXLC-65 | 65 | B | 50 | 25 | 5 | 0.75 | 0.01 | 999,999 |
LXLC-80 | 80 | B | 80 | 40 | 8 | 1.20 | 0.01 | 999,999 |
LXLC-100 | 100 | B | 130 | 60 | 12 | 1.80 | 0.01 | 999,999 |
LXLC-125 | 125 | B | 200 | 100 | 20 | 3.00 | 0.01 | 999,999 |
LXLC-150 | 150 | B | 300 | 150 | 30 | 4.50 | 0.01 | 999,999 |
LXLC-200 | 200 | B | 500 | 250 | 50 | 7.50 | 0.01 | 999,999 |
LXLC-250 | 250 | B | 800 | 400 | 80 | 12.00 | 0.01 | 999,999 |
LXLC-300 | 300 | B | 1200 | 600 | 120 | 18.00 | 0.01 | 999,999 |
LXLC-400 | 400 | B | 2000 | 100 | 200 | 30.00 | 0.01 | 999,999 |
LXLC-500 | 500 | B | 3000 | 1500 | 300 | 45.00 | 0.01 | 999,999 |
DIMENSIONS
Type | Size | Length | Width | Height | Connecting flange (mm ) | Weight | ||
mm | φD1 - Outside diameter | φD2-Bolt circle diameter | Connecting Bolts (n-M) | KG | ||||
LXLC-50 | 50 | 200 | 175 | 257 | 165 | 125 | 4×M16 | 12 |
LXLC-65 | 65 | 200 | 185 | 267 | 185 | 145 | 4×M16 | 13 |
LXLC-80 | 80 | 225 | 200 | 277 | 200 | 160 | 4×M16 | 15 |
LXLC-100 | 100 | 250 | 220 | 287 | 220 | 180 | 4×M16 | 19 |
LXLC-125 | 125 | 250 | 245 | 297 | 245 | 210 | 4×M16 | 22 |
LXLC-150 | 150 | 250 | 285 | 375 | 285 | 240 | 8×M20 | 47 |
LXLC-200 | 200 | 350 | 345 | 400 | 340 | 295 | 8×M20 | 48 |
LXLC-250 | 250 | 350 | 395 | 484 | 385 | 350 | 8×M20 | 110 |
LXLC-300 | 300 | 450 | 445 | 506 | 445 | 400 | 12×M20 | 115 |
LXLC-400 | 400 | 500 | 565 | 621 | 565 | 525 | 16×M24 | 180 |
LXLC-500 | 500 | 500 | 670 | 725 | 670 | 620 | 20×M24 | 330 |