1.1 Device flow range: (20-6300)L/h; 1.2 Device uncertainty: ≤0.2%(K =2) 1.3 Pressure range: 0-2.5 MPa; 1.4 Ambient temperature: 15-30 ℃; 1.5 relative humidity :(45%-75%); 1.6 atmospheric pressure :(86-106)kpa; 1.7 Power supply voltage: 400V±5%, 50HZ; 1.8 air source pressure :(3.5-6)bar; 1.9 Acquisition method: image recognition; 1.10 Equipment power: water pump 1.8KW, heating 6KW; 1.11 Number of inspection tables: ultrasonic table (DN15:10 DN20:10 DN25:6); 1.12 Device size: Length, width and height (5800 mm *650 mm *2000mm)
Availability: | |
---|---|
Quantity: | |
DYCK25-V30-2
S.H.Meters
High Pressure Water Meter Test Bench
Overview
The liquid flow standard device is widely used in the experiment and verification device of liquid flowmeter, especially for flowmeter manufacturers, there are a large number of instrument verification and product development experiments, and a set of efficient and reliable liquid flow standard device is made for them. The event is significant.
Flow regulation control:
The device is equipped with two flow point pipelines, and two electromagnetic flowmeters are used as flow indicating devices. The electromagnetic display of DN2.5 diameter is used below 250L, and the electromagnetic display of DN25 is used above 250L. It is equipped with three flow point pipelines, which are respectively used to adjust Q3\Q2\ Q1 flow point.
Standardizer system
The standard device of the device adopts Sartorius electronic scale, and the device uses 60KG/6000E electronic scale as the standard device, equipped with a commutator to realize dynamic detection mode and improve detection efficiency.
High Pressure Water Meter Test Bench
Overview
The liquid flow standard device is widely used in the experiment and verification device of liquid flowmeter, especially for flowmeter manufacturers, there are a large number of instrument verification and product development experiments, and a set of efficient and reliable liquid flow standard device is made for them. The event is significant.
Flow regulation control:
The device is equipped with two flow point pipelines, and two electromagnetic flowmeters are used as flow indicating devices. The electromagnetic display of DN2.5 diameter is used below 250L, and the electromagnetic display of DN25 is used above 250L. It is equipped with three flow point pipelines, which are respectively used to adjust Q3\Q2\ Q1 flow point.
Standardizer system
The standard device of the device adopts Sartorius electronic scale, and the device uses 60KG/6000E electronic scale as the standard device, equipped with a commutator to realize dynamic detection mode and improve detection efficiency.