Availability: | |
---|---|
Quantity: | |
DN15-DN40
S.H.Meters
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
Accurate measurement: The volumetric water meter adopts the mechanical measurement principle, which can accurately record the water consumption.
Long life span: volumetric water meters have a simple structure, long life span and do not require electricity supply.
Low maintenance cost: volumetric water meters have no electronic components and complex sensors, and do not require frequent maintenance and replacement.
Easy installation: volumetric water meters can be installed on water pipes without taking up much space.
High resistance to interference: volumetric water meters are not affected by external environment, such as temperature, humidity, electromagnetic field, etc.
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
· Body material: Brass body / Plastic body.
· Size: Plastic body: DN15-20; Brass body: DN15-40.
· Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
Accurate measurement: The volumetric water meter adopts the mechanical measurement principle, which can accurately record the water consumption.
Long life span: volumetric water meters have a simple structure, long life span and do not require electricity supply.
Low maintenance cost: volumetric water meters have no electronic components and complex sensors, and do not require frequent maintenance and replacement.
Easy installation: volumetric water meters can be installed on water pipes without taking up much space.
High resistance to interference: volumetric water meters are not affected by external environment, such as temperature, humidity, electromagnetic field, etc.
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
· Body material: Brass body / Plastic body.
· Size: Plastic body: DN15-20; Brass body: DN15-40.
· Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.