Availability: | |
---|---|
Quantity: | |
DN15-DN40
S.H.Meters
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
· Low start-up flow rate.
· Volumetric rotary piston principle of measurement.
· LXHY-15~20 is no location limitation for installation. Accuracy is not to be affected wherever installed at a horizontal, vertical or inclined pipeline.
· Register is sealed with a special liquid to keep a clear reading in long term service.
· Mechanism use of high-quality material to ensure a stable characteristic.
· Accurate measurement with conformity to ISO 4064 class C.
· On request, the series can be equipped with a kind of remote transmission device.
·Material:brass/plasic/nylon
·Features long service time and high accuracy
·Threaded connection mechanical digital water meter, with dry dial, suitable for high pressure environment of various pipelines, can choose whether to install pulse output
·Applicable scenarios: home/apartment/house/garden/malls/residence/municipality
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
Installation location: The volumetric water meter needs to be installed on the water pipe and needs to ensure the correct direction of water flow, otherwise it will affect the accuracy of measurement.
Regular cleaning: The volumetric water meter needs to be cleaned regularly to ensure the accuracy of measurement. Cleaning should be done in accordance with the instructions to avoid damaging the equipment.
Regular calibration: volumetric water meters need to be calibrated regularly to ensure the accuracy of measurement. It is recommended that it be calibrated once a year or in accordance with the requirements in the instructions for use.
Avoid collision: The volumetric water meter is a mechanical device and needs to avoid collision and dropping in order not to affect the use effect.
Avoid moisture: There are many mechanical structures inside the volumetric water meter, so it is necessary to avoid moisture to avoid affecting the service life.
Avoid using hard objects to clean: when cleaning the volumetric water meter, you need to use soft cloth or sponge, avoid using hard objects to clean, so as not to scratch the surface of the equipment.
Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
· Low start-up flow rate.
· Volumetric rotary piston principle of measurement.
· LXHY-15~20 is no location limitation for installation. Accuracy is not to be affected wherever installed at a horizontal, vertical or inclined pipeline.
· Register is sealed with a special liquid to keep a clear reading in long term service.
· Mechanism use of high-quality material to ensure a stable characteristic.
· Accurate measurement with conformity to ISO 4064 class C.
· On request, the series can be equipped with a kind of remote transmission device.
·Material:brass/plasic/nylon
·Features long service time and high accuracy
·Threaded connection mechanical digital water meter, with dry dial, suitable for high pressure environment of various pipelines, can choose whether to install pulse output
·Applicable scenarios: home/apartment/house/garden/malls/residence/municipality
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
Installation location: The volumetric water meter needs to be installed on the water pipe and needs to ensure the correct direction of water flow, otherwise it will affect the accuracy of measurement.
Regular cleaning: The volumetric water meter needs to be cleaned regularly to ensure the accuracy of measurement. Cleaning should be done in accordance with the instructions to avoid damaging the equipment.
Regular calibration: volumetric water meters need to be calibrated regularly to ensure the accuracy of measurement. It is recommended that it be calibrated once a year or in accordance with the requirements in the instructions for use.
Avoid collision: The volumetric water meter is a mechanical device and needs to avoid collision and dropping in order not to affect the use effect.
Avoid moisture: There are many mechanical structures inside the volumetric water meter, so it is necessary to avoid moisture to avoid affecting the service life.
Avoid using hard objects to clean: when cleaning the volumetric water meter, you need to use soft cloth or sponge, avoid using hard objects to clean, so as not to scratch the surface of the equipment.
Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.