DN50-DN300
S.H.Meters
ultrasonic bulk water meter RS485 remote reading
AMI SYSTEM INTRODUCTION SIMPLE IS SMART…..
System structure diagram as follows
· server send commands to the data concentrator through network;
· concentrator transforms the received commands into radio signal and send the signal to the water meters;
· water meters respond and execute the commands accordingly;
· Water meters deliver the result or data back to the management center as per the original route after the actions finished.
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Bulk Water Meter
Features
·Material:cast iron
·Technical data conform to international standard ISO 4064.
·communication:rs485 modbus
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Bulk Water Meter
Working principle
The meter comprises the quality temperature sensor ,the flow sensor and the calculator. The temperature sensor to measure the temperature of water and the flow sensor to measure the volume of water that flow through the pipelines by the transit time difference.
The two data is sent to the calculator after being collected, the consumption water quantity is worked out, stored and indicated on the LCD finally.
Technical parameter
Nominal diameter(mm) | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
Max flow Q4(m3/h) | 50 | 78.75 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 |
Nominal flow Q3(m3/h) | 40 | 63 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
Transitional flow Q2(m3/h) | 0.16 | 0.756 | 0.252 | 0.4 | 0.64 | 1 | 1.6 | 2.52 | 4 |
Min flow Q1(m3/h) | 0.1 | 0.158 | 0.158 | 0.25 | 0.4 | 0.625 | 1 | 1.575 | 2.5 |
Protection class | IP68 | ||||||||
Measuring range | Q3/Q1 R250/R400 | ||||||||
Accuracy class | class 2 | ||||||||
Battery life | 8 years | ||||||||
Temperature class | T50 | ||||||||
Pressure loss class | ΔP63 | ||||||||
Flow prefile sensitivity class | U10/D5 | ||||||||
Environmental class | Class B,M1 | ||||||||
Electromagnetic environment class | E1 | ||||||||
Working pressure | 1.6Mpa | ||||||||
Max flow indication(m3) | 9999999.9 | ||||||||
Reverse flow indication(m3) | 9999999.9 | ||||||||
Installation position | Horizontal or Vertical |
ultrasonic bulk water meter RS485 remote reading
AMI SYSTEM INTRODUCTION SIMPLE IS SMART…..
System structure diagram as follows
· server send commands to the data concentrator through network;
· concentrator transforms the received commands into radio signal and send the signal to the water meters;
· water meters respond and execute the commands accordingly;
· Water meters deliver the result or data back to the management center as per the original route after the actions finished.
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Bulk Water Meter
Features
·Material:cast iron
·Technical data conform to international standard ISO 4064.
·communication:rs485 modbus
·With remote transmission system software to support reading and monitoring
·Provide a complete software metering and charging solution
·Bulk Water Meter
Working principle
The meter comprises the quality temperature sensor ,the flow sensor and the calculator. The temperature sensor to measure the temperature of water and the flow sensor to measure the volume of water that flow through the pipelines by the transit time difference.
The two data is sent to the calculator after being collected, the consumption water quantity is worked out, stored and indicated on the LCD finally.
Technical parameter
Nominal diameter(mm) | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
Max flow Q4(m3/h) | 50 | 78.75 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 |
Nominal flow Q3(m3/h) | 40 | 63 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 |
Transitional flow Q2(m3/h) | 0.16 | 0.756 | 0.252 | 0.4 | 0.64 | 1 | 1.6 | 2.52 | 4 |
Min flow Q1(m3/h) | 0.1 | 0.158 | 0.158 | 0.25 | 0.4 | 0.625 | 1 | 1.575 | 2.5 |
Protection class | IP68 | ||||||||
Measuring range | Q3/Q1 R250/R400 | ||||||||
Accuracy class | class 2 | ||||||||
Battery life | 8 years | ||||||||
Temperature class | T50 | ||||||||
Pressure loss class | ΔP63 | ||||||||
Flow prefile sensitivity class | U10/D5 | ||||||||
Environmental class | Class B,M1 | ||||||||
Electromagnetic environment class | E1 | ||||||||
Working pressure | 1.6Mpa | ||||||||
Max flow indication(m3) | 9999999.9 | ||||||||
Reverse flow indication(m3) | 9999999.9 | ||||||||
Installation position | Horizontal or Vertical |