Material: | |
---|---|
Register: | |
Feature: | |
Water pressure: | |
Application: | |
Thread end type: | |
temperature: | |
Availability: | |
Quantity: | |
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
1. LXHY-15-40 Rotary Piston Liquid Sealed Water Meter
Such water meters can be used in remote meter reading transmission systems with built-in sensors
2. The installation of LXHY-15-40 has no position restrictions, and can be installed in any position on horizontal, vertical or inclined pipes without affecting the accuracy
3. The register is sealed with special liquid, and the reading is clear after long-term use
4. The mechanism adopts high-quality materials to ensure stable performance
5.Accurate measurement according to ISO 4064 Class C
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
· Body material: Brass body / Plastic body.
· Size: Plastic body: DN15-20; Brass body: DN15-40.
· Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.
Application
Measuring the volume of cold portable water passing through the pipeline. Also suitable for pure water.
Operating Condition
· The Max.Admissible water pressure 1.6MPa.
· Resisting water temperature: 50℃.
Features
1. LXHY-15-40 Rotary Piston Liquid Sealed Water Meter
Such water meters can be used in remote meter reading transmission systems with built-in sensors
2. The installation of LXHY-15-40 has no position restrictions, and can be installed in any position on horizontal, vertical or inclined pipes without affecting the accuracy
3. The register is sealed with special liquid, and the reading is clear after long-term use
4. The mechanism adopts high-quality materials to ensure stable performance
5.Accurate measurement according to ISO 4064 Class C
Pulse Position
Magnet Position | Liter/Pulse |
*0.0001 | 1 |
*0.001 | 10 |
Note
· Body material: Brass body / Plastic body.
· Size: Plastic body: DN15-20; Brass body: DN15-40.
· Different register can be choose:
Dial Picture | Measure Unit |
Measure Unit: CBM 8 Wheels Four red, four white wheel. The minimum reading: 1L | |
Measure Unit: CBM 8 Wheels Three red, five white wheel. The minimum reading: 10L | |
Measure Unit:UK Gallon 8 Wheels One red, seven white wheel The minimum reading: 1 UK/Gallon | |
Measure Unit:UK Gallon 8 Wheels All white wheel The minimum reading: 10 UK Gallon | |
Measure Unit:US Gallon 8 Wheels One red, three black, four white wheel The minimum reading: 1 US Gallon |
Dimensions
Description | Unit | Hydraulic Data And Dimensions | |||||
Nominal Size | mm(inch) | DN15 (1/2) | DN20(3/4) | DN25(1) | DN32(1-1/4) | DN40(1-1/2) | |
Q4 Error Limit ±2% | m³/h | 3.125 | 5 | 7.875 | 12.5 | 20 | |
Q3 Error Limit ±2% | m³/h | 2.5 | 4.0 | 6.3 | 10 | 16 | |
Q2 Error Limit ±2% | l/h | 25 | 40 | 63 | 100 | 160 | |
Q1 Error Limit ±5% | l/h | 15.6 | 25 | 39.4 | 62.5 | 100 | |
Min.Reading | l | 0.05 | 0.05 | 0.05 | 0.5 | 0.5 | |
Max.Reading | m³ | 9999.9999 | 9999.9999 | 9999.9999 | 99999.999 | 99999.999 | |
MAP | Mpa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | |
Press Loss P AT Q 3 | Mpa | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | ≤0.063 | |
L | mm | 115 | 165 | 199 | 260 | 300 | |
B | mm | 43 | 43 | 53 | 60 | 77 | |
Weight | Without Connections | Kg | 1.14 | 1.56 | 2.48 | 3.47 | 5.65 |
With Connections | Kg | 0.97 | 1.3 | 2.05 | 2.75 | 4.7 |
Maximum Permissible Error
Warranty
All meters will be guaranteed against defects in workmanship and materials for a period of one (1) year from the date of acceptance. Defective meters or parts discovered within this period shall be replaced without charge upon return to the S.H.Meters.